100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

MRI In Practice Chapter 2 Best Exam Solutions Guaranteed Success.

Rating
-
Sold
-
Pages
6
Grade
A+
Uploaded on
01-04-2025
Written in
2024/2025

Parameters that cannot be changed because they are inherent to the body's tissue - correct answer intrinsic contrast parameters Name the MRI intrinsic contrast parameters - correct answer T1 recovery time, T2 decay time, proton density, flow, apparent diffusion coefficient or ADC Parameters that can be changed, all selected at the operator console, selection depends on the pulse sequence used - correct answer extrinsic contrast parameters Name the MRI extrinsic contrast parameters - correct answer TR, TE, flip angle, TI, turbo factor/echo train length, b value An MRI image has contrast if there are areas of ______ signal or white on the image and areas of _______ signal or dark on the image - correct answer high, low Some areas have an intermediate signal and will display what? - correct answer shades of gray in between black and white The ________ can be separated into the individual vectors or quantities of the tissue present in the patient such as fat, CSF and muscle - correct answer NMV A tissue has a high signal if it has a large ____________ component of coherent magnetization at the time of TE - correct answer transverse If a tissue has a small transverse component of coherent magnetization at time _______ it will return a small signal, resulting in a _______ area on the image - correct answer TE, dark Images obtain contrast mainly through the mechanisms of what? - correct answer T1 recovery, T2 decay and proton or spin density The number of mobile hydrogen protons per unit volume of that tissue - correct answer proton density Water - correct answer Molecules are spaced apart in there and molecular tumbling rate is relatively fast Fat - correct answer Large molecules closely packed together and who is molecular tumbling rate is relatively slow Fat - correct answer Has a low inherent energy and can easily absorb energy into its lattice from hydrogen nuclei Fat - correct answer The NMV of _______ realigns rapidly with B0 so the T1 time of this is short Water - correct answer Has a high inherent energy and cannot easily absorb energy into its lattice from hydrogen nuclei Water - correct answer The NMV of _______ takes longer to realign with B0 so the T1 time of this is long Short - correct answer The T2 decay process in the hydrogen in fat is efficient because the molecules are closely packed together and therefore spin spin interactions are more likely to occur. As a result spins dephase rapidly and the loss of transverse magnetization is rapid. The T2 time of fat is therefore ________ Long - correct answer T2 decay in water is less efficient than in fat, as the molecules are spaced apart and spin spin interactions are less likely to occur. As a result, spins dephase slowly and the loss of transverse magnetization is gradual. The T2 time of water is therefore __________ Fat - correct answer What has a high signal and appears bright on a T1 contrast image? Water - correct answer What has a low signal and appears dark on a T1 contrast image? T1 weighted images - correct answer On what type of image does fat appear bright and water appear dark? Water - correct answer What has a high signal and appears bright on a T2 contrast image? Fat - correct answer What has a low signal and appears dark on a T2 contrast image? T2 weighted images - correct answer On what type of image does water appear bright and fat appear dark? High - correct answer Tissues with a _________ proton density have a large transverse component of magnetization Low - correct answer Tissues with a _________ proton density have a small transverse component of magnetization proton density weighting - correct answer What is always present and depends on the patient and the area being examined. It is the basic MRI contrast Fat - correct answer

Show more Read less
Institution
MRI IN PRACTICE
Module
MRI IN PRACTICE









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
MRI IN PRACTICE
Module
MRI IN PRACTICE

Document information

Uploaded on
April 1, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

MRI In Practice Chapter 2

Parameters that cannot be changed because they are inherent to the body's tissue - correct answer
intrinsic contrast parameters



Name the MRI intrinsic contrast parameters - correct answer T1 recovery time, T2
decay time, proton density, flow, apparent diffusion coefficient or ADC



Parameters that can be changed, all selected at the operator console, selection depends on the pulse
sequence used - correct answer extrinsic contrast parameters



Name the MRI extrinsic contrast parameters - correct answer TR, TE, flip angle, TI,
turbo factor/echo train length, b value



An MRI image has contrast if there are areas of ______ signal or white on the image and areas of
_______ signal or dark on the image - correct answer high, low



Some areas have an intermediate signal and will display what? - correct answer
shades of gray in between black and white



The ________ can be separated into the individual vectors or quantities of the tissue present in the
patient such as fat, CSF and muscle - correct answer NMV



A tissue has a high signal if it has a large ____________ component of coherent magnetization at the
time of TE - correct answer transverse



If a tissue has a small transverse component of coherent magnetization at time _______ it will return a
small signal, resulting in a _______ area on the image - correct answer TE, dark



Images obtain contrast mainly through the mechanisms of what? - correct answer T1
recovery, T2 decay and proton or spin density

, The number of mobile hydrogen protons per unit volume of that tissue - correct answer
proton density



Water - correct answer Molecules are spaced apart in there and molecular tumbling
rate is relatively fast



Fat - correct answer Large molecules closely packed together and who is molecular
tumbling rate is relatively slow



Fat - correct answer Has a low inherent energy and can easily absorb energy into its
lattice from hydrogen nuclei



Fat - correct answer The NMV of _______ realigns rapidly with B0 so the T1 time of
this is short



Water - correct answer Has a high inherent energy and cannot easily absorb energy
into its lattice from hydrogen nuclei



Water - correct answer The NMV of _______ takes longer to realign with B0 so the
T1 time of this is long



Short - correct answer The T2 decay process in the hydrogen in fat is efficient
because the molecules are closely packed together and therefore spin spin interactions are more likely
to occur. As a result spins dephase rapidly and the loss of transverse magnetization is rapid. The T2 time
of fat is therefore ________



Long - correct answer T2 decay in water is less efficient than in fat, as the molecules
are spaced apart and spin spin interactions are less likely to occur. As a result, spins dephase slowly and
the loss of transverse magnetization is gradual. The T2 time of water is therefore __________



Fat - correct answer What has a high signal and appears bright on a T1 contrast
image?

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
RealGrades Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
170
Member since
2 year
Number of followers
52
Documents
11665
Last sold
3 weeks ago

4.0

26 reviews

5
12
4
5
3
7
2
1
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions