100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS Exam Q&A 100% Guaranteed Success

Rating
-
Sold
-
Pages
56
Grade
A+
Uploaded on
14-02-2025
Written in
2024/2025

S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS Exam Q&A 100% Guaranteed Success fire department connection - normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. system control valve - valve controlling flow to water-based fire protection systems. fire command center - Designated room or area in a structure where the status of the fire detection, alarm, and protection systems is displayed and the systems can be manually controlled. Fire pump, automatic standpipe. - A fire pump located at or below street level that supplies the lower 300 feet (91.4 m) of a standpipe system or a combined standpipe and sprinkler system. tags - on closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational

Show more Read less
Institution
S12/S13 Standpipe Sprinkler
Course
S12/S13 Standpipe Sprinkler











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
S12/S13 Standpipe Sprinkler
Course
S12/S13 Standpipe Sprinkler

Document information

Uploaded on
February 14, 2025
Number of pages
56
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

S12 sprinkler test, S13 standpipe test,
Sprinklers segment 5, S-12 CITYWIDE
SPRINKLER SYSTEMS Exam Q&A 100%
Guaranteed Success

fire department connection - ✔✔normally on exterior of building... FDNY can

pump supplemental water into the sprinkler system, standpipe, or other system

furnishing water for fire extinguishment to supplement existing water supplies.

system control valve - ✔✔valve controlling flow to water-based fire protection

systems.

fire command center - ✔✔Designated room or area in a structure where the

status of the fire detection, alarm, and protection systems is displayed and the

systems can be manually controlled.

Fire pump, automatic standpipe. - ✔✔A fire pump located at or below street

level that supplies the lower 300 feet (91.4 m) of a standpipe system or a

combined standpipe and sprinkler system.

tags - ✔✔on closed section valves serving affected areas: area affected, brief

description, occupancy classification, c of f number, estimated time until

operational


Page 1 of 56
©JOSHCLAY 2025/2026. YEAR PUBLISHED 2025.

,Green tag - ✔✔no impairment found in entire system- main control valve

red tag - ✔✔place on main control valve if FULLY out of service... put sprinkler

company name, date of removal from service and anticipated time to

operational

blue disk - ✔✔partially out of service- on all fire department connections

water storage tank - ✔✔Collects cooled water

OS & Y valve - ✔✔indicating type of control valve used for fire sprinkler system

deluge valve - ✔✔water supply control valve intended to be operated by

actuation of an automatic detection system that is installed in the same area as

the discharge devices. INTENDED USE IS MANUAL AND AUTO

deluge sprinkler system - ✔✔employing open sprinklers that are attached to a

piping system that is connected to a water supply through a valve that is

opened by the operation of a detection system installed in the same areas as

the sprinklers. WHEN IT OPENS, water flows into the piping system and

discharges from all sprinklers attached.

Early suppresion fast response sprinklers - ✔✔fast response sprinkler that is

listed for its capability to provide fire suppression of specific high challenge fire

hazards


Page 2 of 56
©JOSHCLAY 2025/2026. YEAR PUBLISHED 2025.

,extra large orifice sprinklers - ✔✔= or > 1 inch less pressure to achieve a given

discharge density

extended coverage sprinkler - ✔✔400 max square feet discharge 20 foot by 20

foot spacing between sprinklers

fire pump - ✔✔a provider of liquid flow and pressure dedicated to fire

protection. A fire pump is a part of a fire sprinklers system water supply and can

be powered by electric, diesel or steam. connected to public water source or

tank. provides higher pressure to sprinkler system

Glass bulb sprinkler - ✔✔operated by heat breaking a glass bulb filled with a

non freezing liquid with diameters that vary form 3 mm for quick response to 5

mm for standard response

hose valve - ✔✔valve to additional hose connection

hydraulic placard - ✔✔sign attached to a hydraulically calculated sprinkler

system indicating the design density, required gallons per minute and pressure

for the system to operate properly

hydraulically calculated systems - ✔✔method of sizing auto sprinkler piping

using a prescribed amount of water to be distributed over a specific area.

impairment coordinator - ✔✔in charge of safety during out of service systems


Page 3 of 56
©JOSHCLAY 2025/2026. YEAR PUBLISHED 2025.

, intermediate level sprinkler - ✔✔sprinkler equipped with integral shields to

protect the operating elemtn form discharge from sprinklers installed at higher

elevations

large orifice sprinkler - ✔✔sprinkler head with orifice size equal or greater than

3/4 and less than 1 inch

listed device - ✔✔A fire protection component that has been tested to perform

under parameters specified for its use by a nationally recognized testing agency.

Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most

common.

Master Pressure Reducing Valve - ✔✔A pressure reducing valve installed to

regulate pressures in an entire fire protection system and/or standpipe system

zone.

Main Drain - ✔✔The primary drain connection located on the system riser and

also utilized as a flow test connection.

Microbiologically Influenced Corrosion (MIC) - ✔✔Corrosion caused by the

presence of microbes in the water supply that over time attack the interior of

metallic piping and cause leaks, pitting, and blockages.




Page 4 of 56
©JOSHCLAY 2025/2026. YEAR PUBLISHED 2025.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
JOSHCLAY West Governors University
View profile
Follow You need to be logged in order to follow users or courses
Sold
236
Member since
2 year
Number of followers
14
Documents
17681
Last sold
16 hours ago
JOSHCLAY

JOSHCLAY EXAM HUB, WELCOME ALL, HERE YOU WILL FIND ALL DOCUMENTS & PACKAGE DEAL YOU NEED FOR YOUR SCHOOL WORK OFFERED BY SELLER JOSHCLAY

3.7

49 reviews

5
21
4
7
3
10
2
5
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions