PLUMBING #1 GENERAL EXAMINATION QUESTIONS WITH COMPLETE ANSWERS

Institución
Advanced Plumbing
Grado
Advanced plumbing









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Advanced plumbing
Grado
Advanced plumbing

Información del documento

Subido en
1 de febrero de 2025
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

PLUMBING #1 GENERAL EXAMINATION
QUESTIONS WITH COMPLETE
ANSWERS
Sheet metal, constituting a part of any vent connector, shall be at least how many
inches. - Answer-0.0304

One material NOT approved for the installation of an external trap for a urinal is.... -
Answer-drawn-copper, alloy tubing traps

Hub and spigot cast-iron piping in 10-foot lengths, installed horizontally, shall be
supported at intervals of not more than ___ feet. - Answer-10 feet

A drain connecting the compartments of a set of fixture to a trap is called a (an) -
Answer-continuous waste

A device to prevent back flow into the potable water system is called a....... - Answer-
backflow preventer

Copper tube and fittings for drainage and vent piping installed above ground shall be at
least ________ - Answer-Type DWV

A ____ shall be permitted to be installed with indirect waste. - Answer-drinking fountain

Vitrified clay pipe and fitting are _____. - Answer-approved for use as a building drain
and shall be kept NOT less than 12 inches below ground.

Cast-iron soil pipe shall NOT be - Answer-threaded

All trenches deeper than the footing of any building or structure and paralleling the
same must be at least _____ from the bottom exterior edge of the footing or as
approved. - Answer-45 degrees

Sewer or other drainage piping that shall not be installed under or within 2 feet of any
building or structure is..... - Answer-SDR 35 sewer pipe

Cast-iron soil pipe shall be supported at.... - Answer-their base and each floor

Water service pipes, or any other underground pipes, shall NOT be run or laid in the
same trench with ______ unless specific conditions are met. - Answer-SDR 35 sewer
piping

, Notifications for inspections of work authorized by the permit shall be made - Answer-
NOT LESS than 24 hrs BEFOREEE the work has to be inspected

What water pipe systems shall be permitted to be tested with air? - Answer-PEX

The MINIMUM size waste pipe for a domestic kitchen sink is how many inches? -
Answer-2 inches

The MINIMUM size trap and trap arm for a kitchen sink is how many inches? - Answer-
1-1/2
One and a half

Horizontal drainage lines connecting with other horizontal shall enter through - Answer-
45 degree Y branches

In each run of horizontal drain piping, the distance between cleanouts shall NOT exceed
- Answer-100 feet

Three-inch horizontal shall be run in practical alignment and at a uniform slope of not
less than _____ inches per foot. How many inches per foot? - Answer-1/4

Where a fixture is installed on a floor level below the elevation of the next upstream
manhole, the fixtures shall be protected from back flow of sewage by installing
_____......... - Answer-a backwater valve

A sewage ejector discharge line shall be provided with a.... - Answer-backwater valve
and gate valve

The MAXIMUM number of water closets on a 3 inch stack is?? - Answer-four

Unless increased for it's entire length, the maximum length for a 1-1/2 inch vent pipe is
___ feet? - Answer-60 feet

The MAXIMUM fixtures units allowed on a 4-inch horizontal drain line with a 2 percent
slope is _____???? - Answer-216

A two inch waste stack will serve a maximum of??? - Answer-eight kitchen sinks

The MINIMUM size of a building sewer shall be determined on the basis of the total
number of fixture units drained by such sewer in accordance with ____? - Answer-table
717.1 fixtures unit loading

A fixture vent pipe increased one pipe size its entire length ____ - Answer-may exceed
the maximum horizontal length otherwise limited by code

A plumbing vent shall terminate no less than ____ - Answer-10 feet from an air intake

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
biggdreamer Havard School
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
248
Miembro desde
2 año
Número de seguidores
68
Documentos
17956
Última venta
2 semanas hace

4.0

38 reseñas

5
22
4
4
3
6
2
2
1
4

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes