100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

559 Journeyman Mechanical Exam HVAC Complete Questions and Answers

Rating
-
Sold
-
Pages
4
Grade
A+
Uploaded on
19-05-2024
Written in
2023/2024

559 Journeyman Mechanical Exam HVAC Complete Questions and Answers Which Type of air-conditoning system is most likely to leak refrigerant into a structure? Direct, Indirect, Evaporative or Split? - CORRECT ANSWER-Direct : 2015 IMC 1103.3.2 When mechanical equipment is located on a flat roof that is more than 30 inches above grade, how far from the roofs edge must the equipment be located before a guard rail is not needed? less than 6', 9', 4' or more than 10'? - CORRECT ANSWER-More than 10' - 2015 IMC 304.11 A mall bathroom exhaust outlet shall terminate a minimum height of ____ feet above an adjoining sidewalk? - CORRECT ANSWER-10 feet above adjoining grade - 2015 IMC 501.3.1 A room that measures 10x20x8 contains a 35,000 BTU wood burning stove in a building classified as unusually tight construction, what size combustions air openings will be required if they are installed directly in a side wall? - CORRECT ANSWER-8.7 square inches (1 square inch per 4,000 BTU) - 2015 IFGC 304.6.1 How many BTUs in one ton of refrigeration? - CORRECT ANSWER-12,000 BTUS - 2015 IMC Definitions p. 17 'Refrigeration Capacity Rating.' Which refrigerant is not classified as a flammable refrigerant? - CORRECT ANSWERClass 1 - 2015 IMC Definitions p. 13 'Flammability Classifications' Grounded circuit conductor shall be identified by a covering or marking by which of the following colors: A) White or Gray B) Green, C) Black or D) Red? - CORRECT ANSWER-White or Gray - 2014 NEC 200.6 What is the minimum distance to a property line that a supply air intake can be located? - CORRECT ANSWER-10' - 2015 IMC 401.4 How many pounds per 1,000 cubic feet of occupied space of R-410A refrigerant can be in a direct system? - CORRECT ANSWER-26 pounds - 2015 IMC Table 1103.1 Which of the following systems is required by code to be periodically tested per the manufacturer's instructions and as required by the code official: Fuel Gas Piping, Venting Systems, Air duct systems or Refrigerant Alarm Systems? - CORRECT ANSWER-Refrigerant Alarm Systems - 2015 IMC 1109.1 A room contains a gas-fired furnace with an input rating of 108,000 BTUs. The room is 20'x10'x8'. Is the room classified as a confined space? Yes or no. - CORRECT ANSWER-Yes (Needs to be 50 cubic feet per 1,000 BTU) - 2015 IFGC 304.51 What is the full load current rating of a 230-volt, three phase alternating current motor rated at 7.5 horsepower? - CORRECT ANSWER-22 amps - 2014 NEC Table 430.250 (Motors, Motor Circuits and Controllers) p. 70-351 What is the maximum flame spread and smoke development ratings for duct covering insulation in an assembly occupancy? - CORRECT ANSWER-25 flame spread, 50 smoke development ratings - 2015 IMC 604.3 For a duct to penetrate a fire partition without the installation of a fire damper the partition opening must be lined with a steel sleeve of what thickness? - CORRECT ANSWER-.060-inch-thick - 2015 IMC 607.5.3 Fire dampers shall comply with the requirements of what standard for testing? - CORRECT ANSWER-UL 555 - 2015 IMC 607.3.1 What size copper conductor is required for a branch circuit using type THHW 75°C conductor installed in a racewa

Show more Read less
Institution
Hvac
Course
Hvac








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Hvac
Course
Hvac

Document information

Uploaded on
May 19, 2024
Number of pages
4
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
StudyCenter1 Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
221
Member since
2 year
Number of followers
91
Documents
3854
Last sold
1 week ago
Nursing school is hard! Im here to simply the information and make it easier!

My mission is to be your LIGHT in the dark. If you"re worried or having trouble in nursing school, I really want my notes to be your guide! I know they have helped countless others get through and thats all i want for YOU! Stay with me and you will find everything you need to study and pass any tests,quizzes abd exams!

4.3

27 reviews

5
18
4
4
3
3
2
0
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions