100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NFPA 90B Residential Warm Air Heating Systems Exam With Actual Questions & Verified Answers,Plus Rationales/Expert Verified For Guaranteed Pass /2026 /Latest Update/Instant Download Pdf

Puntuación
-
Vendido
-
Páginas
32
Grado
A+
Subido en
11-01-2026
Escrito en
2025/2026

NFPA 90B Residential Warm Air Heating Systems Exam With Actual Questions & Verified Answers,Plus Rationales/Expert Verified For Guaranteed Pass /2026 /Latest Update/Instant Download Pdf

Institución
NFPA 90B Residential Warm Air Heating Systems
Grado
NFPA 90B Residential Warm Air Heating Systems











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NFPA 90B Residential Warm Air Heating Systems
Grado
NFPA 90B Residential Warm Air Heating Systems

Información del documento

Subido en
11 de enero de 2026
Número de páginas
32
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NFPA 90B Residential Warm Air
Heating Systems Exam With Actual
Questions & Verified Answers,Plus
Rationales/Expert Verified For
Guaranteed Pass /2026 /Latest
Update/Instant Download Pdf

1. What is the primary purpose of NFPA 90B?
A. To regulate industrial furnace design
B. To prevent fire and smoke hazards in residential warm air
heating systems
C. To mandate energy efficiency standards
D. To establish plumbing codes
B. To prevent fire and smoke hazards in residential warm air heating
systems
Rationale: NFPA 90B provides minimum requirements to protect life
and property from fire and smoke hazards in residential warm air
heating and air-conditioning systems.
2. Which type of duct material is generally prohibited in
residential warm air heating systems?
A. Galvanized steel
B. Flexible metal
C. Plastic
D. Aluminum

,C. Plastic
Rationale: NFPA 90B prohibits combustible materials such as plastic
for ducts in residential warm air heating systems because they can
easily ignite.
3. What is the minimum clearance required between a warm air
furnace and combustible materials?
A. 1 inch
B. 3 inches
C. 6 inches
D. As specified by the manufacturer
D. As specified by the manufacturer
Rationale: NFPA 90B requires following the manufacturer’s
installation instructions for clearances to combustibles. If
instructions are not provided, default clearances per the standard
should be used.
4. What is the maximum allowable temperature rise across a
residential warm air furnace?
A. 50°F
B. 90°F
C. 100°F
D. 150°F
B. 90°F
Rationale: NFPA 90B specifies a maximum temperature rise of 90°F
across the furnace to prevent overheating and potential fire
hazards.
5. Residential warm air heating systems must have return air
openings sized to prevent:
A. Excessive noise
B. Air filter replacement

, C. Furnace overheating
D. Duct leakage
C. Furnace overheating
Rationale: Adequate return air ensures the furnace does not
overheat, which could create a fire hazard.
6. What is the required rating for a furnace filter in residential
systems?
A. UL 900
B. ASTM D228
C. ISO 16890
D. None
A. UL 900
Rationale: Filters must comply with UL 900 to ensure they are safe
for use in HVAC systems and do not pose a fire hazard.
7. How must ducts passing through combustible construction be
protected?
A. With asbestos wrapping
B. With sheet metal sleeve or equivalent
C. No protection is needed
D. With fiberglass insulation only
B. With sheet metal sleeve or equivalent
Rationale: NFPA 90B requires that ducts passing through
combustible materials be enclosed in a noncombustible sleeve to
prevent fire spread.
8. What is the maximum distance a single furnace duct can extend
without a smoke detector in the duct?
A. 10 feet
B. 25 feet

, C. 50 feet
D. NFPA 90B does not require duct smoke detectors in
residential systems
D. NFPA 90B does not require duct smoke detectors in residential
systems
Rationale: Duct smoke detectors are typically required in
commercial applications (NFPA 90A); NFPA 90B focuses on
residential systems and does not mandate them.
9. What is the minimum return air area required for a residential
furnace?
A. 1 square inch per 1000 BTU/hr
B. 1 square inch per 400 BTU/hr
C. 1 square inch per 100 BTU/hr
D. 1 square inch per 500 BTU/hr
B. 1 square inch per 400 BTU/hr
Rationale: NFPA 90B requires return air openings to prevent
overheating and maintain proper airflow. The sizing ratio is
generally 1 in² per 400 BTU/hr.
10. What is the maximum allowable pressure in a residential
warm air duct system?
A. 1 inch water gauge
B. 2 inches water gauge
C. 0.5 inch water gauge
D. 3 inches water gauge
C. 0.5 inch water gauge
Rationale: NFPA 90B recommends a maximum pressure of 0.5 inch
WG to prevent duct leakage and maintain safety.
$21.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
prex

Conoce al vendedor

Seller avatar
prex Teachme2-tutor
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
3 meses
Número de seguidores
0
Documentos
209
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes