100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

FDNY s15 Supervision Of Foam-Water Sprinkler Systems (Citywide) Exam Questions And Correct Answers With Rationales 2026

Puntuación
-
Vendido
-
Páginas
35
Grado
A+
Subido en
03-01-2026
Escrito en
2025/2026

This document covers the updated FDNY S-15 Supervision of Foam-Water Sprinkler Systems material with comprehensive questions and correct, verified answers aligned with FDNY Fire Code, NFPA 16, NFPA 13, and NFPA 25 requirements. It includes all key topics tested for the S-15 Certificate of Fitness, such as foam types, proportioning methods, system components, inspection and testing procedures, maintenance responsibilities, discharge requirements, environmental considerations, and supervisory duties. The content is structured to support focused study and confident preparation for the FDNY S-15 certification exam.

Mostrar más Leer menos
Institución
FDNY S15 Supervision Of Foam-Water Sprinkler
Grado
FDNY s15 Supervision Of Foam-Water Sprinkler











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
FDNY s15 Supervision Of Foam-Water Sprinkler
Grado
FDNY s15 Supervision Of Foam-Water Sprinkler

Información del documento

Subido en
3 de enero de 2026
Número de páginas
35
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

FDNY s15 Supervision Of Foam-Water
Sprinkler Systems (Citywide) Exam
Questions And Correct Answers With
Rationales 2026

1. What is the primary purpose of a foam-water sprinkler system?
A. To suppress Class A fires only
B. To control and extinguish flammable liquid (Class B) fires
C. To provide cooling only
D. To detect fires through heat sensors
Rationale: Foam-water systems are designed for Class B hazards involving
flammable liquids by forming a foam blanket that suppresses vapors and
cools surfaces._



2. What foam type is most commonly used in foam-water sprinkler
systems protecting hydrocarbon fuels?
A. AFFF (Aqueous Film Forming Foam)

,B. Protein foam
C. Alcohol-resistant foam
D. Fluoroprotein foam
Rationale: AFFF forms a thin film that rapidly spreads over hydrocarbon
fuel surfaces, providing quick vapor suppression._



3. Alcohol-resistant foams are specifically designed for what type of fuels?
A. Hydrocarbons
B. Polar solvents
C. Combustible solids
D. Organic peroxides
Rationale: Polar solvents dissolve regular foams, so alcohol-resistant foam
creates a polymer membrane to protect the foam layer._



4. Which component mixes foam concentrate with water in the proper
proportion?
A. Foam nozzle
B. Foam proportioner
C. Foam generator
D. Concentrate pump
Rationale: The proportioner ensures the correct concentrate-to-water
ratio, essential for foam effectiveness._

,5. What is the standard foam concentrate proportion for AFFF in most
systems?
A. 1%
B. 3% or 6%
C. 10%
D. 15%
Rationale: AFFF concentrates are formulated for 3% or 6% mixtures,
depending on hazard type and manufacturer._



6. Which NFPA standard governs foam-water sprinkler systems?
A. NFPA 13
B. NFPA 16
C. NFPA 25
D. NFPA 30
Rationale: NFPA 16 provides installation and maintenance standards for
foam-water sprinkler and spray systems._



7. Foam-water sprinkler systems are classified as what type of system
under NFPA 16?
A. Hybrid fire protection system
B. Dry chemical system

, C. Standpipe system
D. Gaseous suppression system
Rationale: Foam-water systems combine properties of foam and water
systems, making them hybrid systems._



8. The main extinguishing action of foam is by:
A. Cooling the fire area
B. Diluting fuel concentration
C. Smothering and separating the fuel from oxygen
D. Increasing air humidity
Rationale: Foam isolates the fuel surface from air, suppressing vapor and
oxygen contact._



9. Which type of foam system is automatically activated by a heat detector
network?
A. Foam-water sprinkler system
B. Manual foam monitor system
C. Mobile foam unit
D. Portable extinguisher system
Rationale: Foam-water sprinkler systems use detection and activation
similar to standard automatic sprinklers._
$11.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
KelvinBrooks West Virgina University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
267
Miembro desde
1 año
Número de seguidores
6
Documentos
3059
Última venta
1 día hace
Brooks

Welcome to Brooks Study guides! The place to find the best study materials for various subjects. You can be assured that you will receive only the best which will help you to ace your exams. All the materials posted are A+ Graded. Thank you very much!

4.1

31 reseñas

5
14
4
6
3
10
2
1
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes